3-8 P/N 8040540
C
HELIX TECHNOLOGY CORPORATION
-
TI C
RY
OG
EN
ICS
Disconnecting
1. Using two wrenches as shown in Figure 3-3, disconnect the two
self sealing coupling connectors quickly to minimize helium
leakage.
Figure 3-3: Connecting/Disconnecting Helium Flex Line Self Sealing Couplings
This 1 3/16 in. wrench
is used to turn the self
sealing coupling
connector.
This 1 1/8 in. wrench
holds the coupling in a
stationary position.
Side View
To Tighten Coupling Halves
Hold Here
Tur n He re
Hold Here
Tur n He re
To Loosen Coupling Halves